JEOL-8230 electron microprobe database (CU Boulder) | Print date: 12/15/2017 (23:59)

feedback

warning NEWS December 15th, 2017 *** The new water chiller installation is almost complete, and the chiller is actually running. The probe should re-open around Wednesday December 20th, pending some remaining tests and minor fix..

X-ray mapping - Map calculator

Calculate the right setting for your WDS element mapping or load an existing one from the list aside the title.
WARNING: Time estimation is accurate for a beam scan. However, there is a delay of several seconds at the end of each line during a stage scan.
For instance, a delay of 3 to 5 seconds has been observed on CAMECA SX-50, which could be worse if the stage needs to move back after each line...

INPUT

Top:
Left: help Right:
Bottom:
 
Mapping for JEOL-8230
Image size X [px]... help
Image size Y [px]...
Step size [µm/px]...
Force maximum X-pixels help
Image size X [px]
Image size Y [px]
Step size [µm/px]
Time input... help
Select (on the right): (a) dwell time, (b) total analysis time in hours or (c) in minutes.
a) Dwell time [ms/px]
b) Total [h]
c) Total [min]
Reset the form
Enter X (horizontal) and Y (vertical) coordinates for the region to map. Value for top (or right) must be higher than value for bottom (or left).

Maximum values in mm constrained by the stage limit are...

For JEOL-8230:
- LEFT (X) = -57
- RIGHT (X) = 42
- TOP (Y) = 37
- BOTTOM (Y) = -42

These limits can be adjusted in the file "preferences.inc.php"; ask your webmaster!
Select the EMP to use. This will only limit the maximum number of pixel per map.
Choose your calculation option on the right and enter on the left the required value:
- Image size in pixels along X or
- Image size in pixels along Y or
- Step size in micrometer per pixel.

Note: the maximum image size is 5120 pixels for JEOL-8230..
ONLY AVAILABLE WITH THE OPTION "STEP SIZE"...

If checked, this options will force a maximum size for your map. It will take the maximum amount of pixel allowed at the selected electron microprobe, and multiply this value by the selected step size. It will then adjust the X position (left and right) in consequence. This can be useful for full thin section map, or to get the largest map at a specific step size.
Choose your calculation option on the right and enter the time constraint on the right:
- Dwell time (countintg time on each pixel) or
- Total acquisition time (in hours or minutes).

Colorado University at Boulder - EMP facility © 2016
Webmaster (Julien Allaz): julien.allaz@colorado.edu | Lab manager (Julien Allaz, Kevin Mahan): julien.allaz@colorado.edu, cailey.condit@colorado.edu, omero.orlandini@colorado.edu

Will open in a new page...

Colorado University at Boulder - EMP facility © 2016 | Julien Allaz, Kevin Mahan
Last update: February 4th, 2017 (copyright) | Contact

Memory usage: 130.2 kb || Page generated in 0.0295 s
Server date (time): Dec 15, 2017 (23:59)